Tankguard NCV N phenolic epoxy
China-based distributor of Jotun industrial protective coatings — supplied from the China production base to projects worldwide.
This model belongs to the categories below; select a tag to see every model in that category.
Tankguard NCV N — product overview
This is a two-component phenolic epoxy product, typically used as primer / intermediate coat. It is characterised by chemical-resistant; service environment atmospheric exposure / immersion service; suitable for protective coating of carbon steel / stainless steel.
Tankguard NCV N — positioning
Jotun's Tankguard NCV N is a phenolic epoxy primer / intermediate coat for atmospheric exposure / immersion service conditions, supplied with its technical documentation.
Within a coating system it can take the appropriate coat for steelwork, tanks and pipelines; the coat sequence and thickness follow the manufacturer's recommended scheme.
The model is notable for chemical-resistant.
It is used for protective coating work in atmospheric exposure / immersion service conditions.
Tankguard NCV N — key data
| Model | Tankguard NCV N |
|---|---|
| Manufacturer product name | 6F2 |
| Resin system | phenolic epoxy |
| Components | two-component |
| Typical number of coats | primer / intermediate coat |
| Service environment | atmospheric exposure / immersion service |
| Suitable substrates | carbon steel / stainless steel |
| Key characteristics | chemical-resistant |
| Colour range | Light grey / light red |
| Application method | airless spray / brush / roller |
| Surface preparation grade | sa 2½ |
| Volume solids | 73 % ± 2 % |
| Density (specific gravity) | 1.6 kg/l |
| Flash point | 33 °C |
| Gloss | Semi-gloss (35-70) |
| Packaging and delivery | Supplied in full drums or full pallets, with staged deliveries to match the progress on site; pack sizes are confirmed per model |
| Source | Manufacturer technical data sheet (jotun-tankguard-ncv-n.pdf) |
Application and system notes
Application: airless spray / brush / roller (sa 2½). Before application, confirm the surface preparation grade and control ambient temperature and humidity, substrate temperature and dew point as the manufacturer requires; observe the specified recoat intervals.
Drying and curing times
| Substrate temperature | -5 °C | 0 °C | 5 °C | 10 °C | 15 °C | 23 °C | 40 °C |
|---|---|---|---|---|---|---|---|
| Touch dry | 12 h | 10 h | 5 h | 4 h | 3 h | 2 h | 1 h |
| Walk-on dry | 48 h | 30 h | 16 h | 12 h | 10 h | 8 h | 4 h |
| Recoat, minimum | 24 h | 20 h | 10 h | 8 h | 6 h | 4 h | 2 h |
| Dried/cured for service | 30 d | 21 d | 14 d | 10 d | 8 d | 6 d | 3 d |
Data taken from the manufacturer's TDS jotun-tankguard-ncv-n.pdf (page 4); 23 °C is the reference condition, the other columns are given for application in different seasons and regions. The full data sheet is available from us on request.
Coat sequence, film thickness and quantity depend on the service conditions (carbon steel / stainless steel / atmospheric exposure / immersion service) and the design life: give us the structure type, corrosivity category and area, and the quantity can be calculated.
Standards and approvals
- GB 30981.2
- GB 30981.2-2025
- ISO 2813
- ISO 3233
- ISO 3679
- ISO 8501-1
Standard numbers are given for selection checks; valid, in-date documents for formal tenders or acceptance are supplied per model.
Tankguard NCV N — requesting technical data
Quotations and application plans rest on film thickness, spreading rate and curing time — all taken from the original TDS.
Full documentation — TDS, SDS, test and certification documents — is available on request: quote the model Tankguard NCV N and the intended use.
Tankguard NCV N — common questions
How is the recoat interval for Tankguard NCV N controlled?
The minimum and maximum recoat intervals follow the manufacturer's TDS and must also satisfy the on-site temperature, humidity and dew point conditions.
Which substrates can Tankguard NCV N be used on?
The TDS lists the substrate as carbon steel / stainless steel; surface preparation must be completed and cleanliness and roughness confirmed, and ambient temperature, humidity and dew point must be within limits before coating.
What service environment suits Tankguard NCV N?
The service environment for this model is atmospheric exposure / immersion service. The corrosivity category determines the coat sequence and film thickness; send the project conditions and the specific build-up can be given.
Models related to Tankguard NCV N
Back to Products to filter every model by use or type
Model and category information on this page is compiled from the manufacturer's technical data sheets and is provided for selection reference; parameters, application requirements and suitability are governed by the manufacturer's latest technical data sheet and by the actual site conditions. This site does not replace the manufacturer's documents.
Sales & technical support
Detailed data and a quotation for Tankguard NCV N
We supply Jotun industrial coatings made in China and handle the export. Get in touch.
- WhatsApp Start a chat