Tankguard SF phenolic epoxy
China-based distributor of Jotun industrial protective coatings — supplied from the China production base to projects worldwide.
This model belongs to the categories below; select a tag to see every model in that category.
Tankguard SF — product overview
This is a two-component phenolic epoxy product, typically used as primer / intermediate coat / topcoat. It is characterised by chemical-resistant; service environment atmospheric exposure / immersion service; suitable for protective coating of carbon steel / galvanised steel / stainless steel / concrete.
Tankguard SF — positioning
Jotun's Tankguard SF is a phenolic epoxy primer / intermediate coat / topcoat for atmospheric exposure / immersion service conditions, supplied with its technical documentation.
Within a coating system it can take the appropriate coat for steelwork, tanks and pipelines; the coat sequence and thickness follow the manufacturer's recommended scheme.
Where chemical-resistant are specified, it combines with other products of the same system into a complete scheme.
It is used for protective coating work in atmospheric exposure / immersion service conditions.
Tankguard SF — key data
| Model | Tankguard SF |
|---|---|
| Manufacturer product name | 0GE |
| Resin system | phenolic epoxy |
| Components | two-component |
| Typical number of coats | primer / intermediate coat / topcoat |
| Service environment | atmospheric exposure / immersion service |
| Suitable substrates | carbon steel / galvanised steel / stainless steel / concrete |
| Key characteristics | chemical-resistant |
| Colour range | Light yellow / Light grey / light red / White |
| Application method | airless spray / brush |
| Surface preparation grade | sa 2½ |
| Volume solids | 100 % |
| Density (specific gravity) | 1.5 kg/l |
| Flash point | 100 °C |
| Gloss | Gloss (70-85) |
| Packaging and delivery | Supplied in full drums or full pallets, with staged deliveries to match the progress on site; pack sizes are confirmed per model |
| Source | Manufacturer technical data sheet (jotun-tankguard-sf.pdf) |
Application and system notes
Application: airless spray / brush (sa 2½). Before application, confirm the surface preparation grade and control ambient temperature and humidity, substrate temperature and dew point as the manufacturer requires; observe the specified recoat intervals.
Drying and curing times
| Substrate temperature | 10 °C | 15 °C | 23 °C | 30 °C | 40 °C |
|---|---|---|---|---|---|
| Touch dry | 15 h | 12 h | 6 h | 5 h | 1.5 h |
| Walk-on dry | 30 h | 24 h | 12 h | 9 h | 4 h |
| Recoat, minimum | 30 h | 24 h | 12 h | 7 h | 4 h |
| Dried/cured for service | 15 d | 10 d | 3 d | 2 d | 1 d |
Data taken from the manufacturer's TDS jotun-tankguard-sf.pdf (page 4); 23 °C is the reference condition, the other columns are given for application in different seasons and regions. The full data sheet is available from us on request.
Usually applied as primer / intermediate coat / topcoat; the number of coats and the quantity per unit depend on the surface condition of the carbon steel / galvanised steel / stainless steel / concrete and the corrosivity of the atmospheric exposure / immersion service environment.
Standards and approvals
- GB 30981-2020
- ISO 2813
- ISO 3233
- ISO 3679
- ISO 8501-1
- NACE No. 6
Standard numbers are given for selection checks; valid, in-date documents for formal tenders or acceptance are supplied per model.
Tankguard SF — requesting technical data
Volume solids, single-coat dry film thickness, recoat interval, drying time and VOC are as stated in the manufacturer's TDS.
Full documentation — TDS, SDS, test and certification documents — is available on request: quote the model Tankguard SF and the intended use.
Tankguard SF — common questions
How is the recoat interval for Tankguard SF controlled?
The minimum and maximum recoat intervals follow the manufacturer's TDS and must also satisfy the on-site temperature, humidity and dew point conditions.
Which substrates can Tankguard SF be used on?
The TDS lists the substrate as carbon steel / galvanised steel / stainless steel / concrete; surface preparation must be completed and cleanliness and roughness confirmed, and ambient temperature, humidity and dew point must be within limits before coating.
What service environment suits Tankguard SF?
The service environment for this model is atmospheric exposure / immersion service. The corrosivity category determines the coat sequence and film thickness; send the project conditions and the specific build-up can be given.
Models related to Tankguard SF
- Jotaprime 510
- Tankguard Plus
- Tankguard Storage HS
- Tankguard Type III
- Tankguard Type II
- Tankguard NCV
Back to Products to filter every model by use or type
Model and category information on this page is compiled from the manufacturer's technical data sheets and is provided for selection reference; parameters, application requirements and suitability are governed by the manufacturer's latest technical data sheet and by the actual site conditions. This site does not replace the manufacturer's documents.
Sales & technical support
Detailed data and a quotation for Tankguard SF
We supply Jotun industrial coatings made in China and handle the export. Get in touch.
- WhatsApp Start a chat