Offshore steel structures and ship coating (heavy-duty)
Model

Tankguard Storage phenolic epoxy

Tankguard Storage (0LD) — in the Jotun range — is a phenolic epoxy product normally used as intermediate coat / topcoat where atmospheric exposure / immersion service conditions apply. This model offers chemical-resistant. For the complete technical data, request the manufacturer's TDS and SDS for Tankguard Storage.

China-based distributor of Jotun industrial protective coatings — supplied from the China production base to projects worldwide.

This model belongs to the categories below; select a tag to see every model in that category.

Tankguard Storage — product overview

A two-component phenolic epoxy coating, normally used as intermediate coat / topcoat: key features chemical-resistant; used in atmospheric exposure / immersion service; suitable on carbon steel / galvanised steel / stainless steel / concrete.

Tankguard Storage — positioning

Tankguard Storage belongs to the phenolic epoxy family of Jotun protective coatings and is used as intermediate coat / topcoat in atmospheric exposure / immersion service service.

The substrate for this product is carbon steel / galvanised steel / stainless steel / concrete. Prepare the surface as the manufacturer requires, and check ambient temperature, humidity and dew point before starting.

The model is notable for chemical-resistant.

Service environments include atmospheric exposure / immersion service; send the actual conditions for anything outside that range.

Tankguard Storage — key data

ModelTankguard Storage
Manufacturer product name0LD
Resin systemphenolic epoxy
Componentstwo-component
Typical number of coatsintermediate coat / topcoat
Service environmentatmospheric exposure / immersion service
Suitable substratescarbon steel / galvanised steel / stainless steel / concrete
Key characteristicschemical-resistant
Colour rangeLight grey / light red / White
Application methodairless spray / brush / roller
Surface preparation gradesa 2½
Volume solids63 % ± 2 %
Density (specific gravity)1.6 kg/l
Flash point28 °C
GlossMatt (0-35)
Packaging and deliverySupplied in full drums or full pallets, with staged deliveries to match the progress on site; pack sizes are confirmed per model
SourceManufacturer technical data sheet (jotun-tankguard-storage.pdf)

Application and system notes

Application: airless spray / brush / roller (sa 2½). Before application, confirm the surface preparation grade and control ambient temperature and humidity, substrate temperature and dew point as the manufacturer requires; observe the specified recoat intervals.

Drying and curing times

Substrate temperature10 °C15 °C23 °C30 °C40 °C
Touch dry15 h12 h4 h3 h2 h
Walk-on dry24 h20 h10 h8 h4 h
Recoat, minimum24 h20 h10 h7 h4 h
Dried/cured for service21 d14 d7 d4 d3 d

Data taken from the manufacturer's TDS jotun-tankguard-storage.pdf (page 4); 23 °C is the reference condition, the other columns are given for application in different seasons and regions. The full data sheet is available from us on request.

Usually applied as intermediate coat / topcoat; the number of coats and the quantity per unit depend on the surface condition of the carbon steel / galvanised steel / stainless steel / concrete and the corrosivity of the atmospheric exposure / immersion service environment.

Standards and approvals

Standard numbers are given for selection checks; valid, in-date documents for formal tenders or acceptance are supplied per model.

Tankguard Storage — requesting technical data

Volume solids, single-coat dry film thickness, recoat interval, drying time and VOC are as stated in the manufacturer's TDS.

To get the manufacturer TDS and SDS for Tankguard Storage, send a request at the foot of this page, or contact us on WhatsApp or by email.

Tankguard Storage — common questions

How many components does Tankguard Storage have, and how is it mixed?

This model is a two-component product. Mixing ratio, pot life and induction time follow the manufacturer's TDS; deviation from the ratio affects curing and adhesion.

Where can I find the technical data for Tankguard Storage?

Volume solids, film thickness, spreading rate, drying time and VOC are as stated in the manufacturer's TDS; the current version for this model is available from us.

Which coat does Tankguard Storage take in the system?

This model is typically used as intermediate coat / topcoat. The number of coats and film thickness depend on the substrate, the corrosivity category and the design life.

Models related to Tankguard Storage

Back to Products to filter every model by use or type

Model and category information on this page is compiled from the manufacturer's technical data sheets and is provided for selection reference; parameters, application requirements and suitability are governed by the manufacturer's latest technical data sheet and by the actual site conditions. This site does not replace the manufacturer's documents.

Sales & technical support

Detailed data and a quotation for Tankguard Storage

We supply Jotun industrial coatings made in China and handle the export. Get in touch.

WeChat QR code