Offshore steel structures and ship coating (heavy-duty)
Model

Penguard HSP E epoxy

Jotun's Penguard HSP E is a epoxy primer / intermediate coat for atmospheric exposure conditions, supplied with its technical documentation. This model offers fast-drying / high solids / high-build. For the complete technical data, request the manufacturer's TDS and SDS for Penguard HSP E.

China-based distributor of Jotun industrial protective coatings — supplied from the China production base to projects worldwide.

This model belongs to the categories below; select a tag to see every model in that category.

Penguard HSP E — product overview

two-component epoxy product for use as primer / intermediate coat; fast-drying / high solids / high-build; substrates carbon steel / galvanised steel / stainless steel; service environment atmospheric exposure.

Penguard HSP E — positioning

Penguard HSP E (0N3) is the epoxy primer / intermediate coat in the Jotun range; this page sets out its system position, parameters and supply.

Within a coating system it can take the appropriate coat for steelwork, tanks and pipelines; the coat sequence and thickness follow the manufacturer's recommended scheme.

The model is notable for fast-drying / high solids / high-build.

Typical service environment: atmospheric exposure.

Penguard HSP E — key data

ModelPenguard HSP E
Manufacturer product name0N3
Resin systemepoxy
Componentstwo-component
Typical number of coatsprimer / intermediate coat
Service environmentatmospheric exposure
Suitable substratescarbon steel / galvanised steel / stainless steel
Key characteristicsfast-drying / high solids / high-build
Colour rangeA range of colours (colour card on request)
Application methodairless spray / brush
Surface preparation gradesa 2½ / sa 2 / st 2
Volume solids75 % ± 2 %
Density (specific gravity)1.64 kg/l
Flash point27 °C
GlossMatt (0-35)
Packaging and deliverySupplied in full drums or full pallets, with staged deliveries to match the progress on site; pack sizes are confirmed per model
SourceManufacturer technical data sheet (jotun-penguard-hsp-e.pdf)

Application and system notes

Application: airless spray / brush (sa 2½ / sa 2 / st 2). Before application, confirm the surface preparation grade and control ambient temperature and humidity, substrate temperature and dew point as the manufacturer requires; observe the specified recoat intervals.

Drying and curing times

Substrate temperature0 °C5 °C10 °C23 °C40 °C
Touch dry11 h5 h2 h1 h30 min
Walk-on dry18 h12 h6 h3 h2 h
Recoat, minimum18 h12 h4 h2 h1 h
Dried/cured for service21 d13 d8 d4 d3 d

Data taken from the manufacturer's TDS jotun-penguard-hsp-e.pdf (page 4); 23 °C is the reference condition, the other columns are given for application in different seasons and regions. The full data sheet is available from us on request.

Usually applied as primer / intermediate coat; the number of coats and the quantity per unit depend on the surface condition of the carbon steel / galvanised steel / stainless steel and the corrosivity of the atmospheric exposure environment.

Standards and approvals

The standard numbers above come from the manufacturer's technical data sheet; original certificates and their conditions of validity can be supplied, or checked against the manufacturer's documents.

Penguard HSP E — requesting technical data

Volume solids, single-coat dry film thickness, recoat interval, drying time and VOC are as stated in the manufacturer's TDS.

To get the manufacturer TDS and SDS for Penguard HSP E, send a request at the foot of this page, or contact us on WhatsApp or by email.

Penguard HSP E — common questions

What are the minimum order quantity and lead time for Penguard HSP E?

Supply is in full drums or full pallets, with staged deliveries to match the application programme. Coatings are flammable dangerous goods carried by licensed carriers; lead time is confirmed by model and quantity.

What are the key characteristics of Penguard HSP E?

This model offers fast-drying / high solids / high-build. Suitability for a particular service condition still has to be assessed together with the complete coating system.

How is the recoat interval for Penguard HSP E controlled?

The minimum and maximum recoat intervals follow the manufacturer's TDS and must also satisfy the on-site temperature, humidity and dew point conditions.

Models related to Penguard HSP E

Back to Products to filter every model by use or type

Model and category information on this page is compiled from the manufacturer's technical data sheets and is provided for selection reference; parameters, application requirements and suitability are governed by the manufacturer's latest technical data sheet and by the actual site conditions. This site does not replace the manufacturer's documents.

Sales & technical support

Detailed data and a quotation for Penguard HSP E

We supply Jotun industrial coatings made in China and handle the export. Get in touch.

WeChat QR code
Scan to add us on WeChat