Penguard Express WF II auxiliary material
China-based distributor of Jotun industrial protective coatings — supplied from the China production base to projects worldwide.
This model belongs to the categories below; select a tag to see every model in that category.
Penguard Express WF II — product overview
This is a one-component auxiliary material product, typically used as inhibitor. It is characterised by fast-drying / high-build; service environment as the system requires; suitable for protective coating of carbon steel / galvanised steel / stainless steel / concrete.
Penguard Express WF II — positioning
Penguard Express WF II (6X7) — in the Jotun range — is a auxiliary material product normally used as inhibitor where as the system requires conditions apply.
Three things decide the system: the substrate (carbon steel / galvanised steel / stainless steel / concrete), the service environment (as the system requires) and the design life. Together they set the number of coats and the total film thickness.
It suits projects where fast-drying / high-build matters — tight application windows or demanding maintenance regimes.
Service environments include as the system requires; send the actual conditions for anything outside that range.
Penguard Express WF II — key data
| Model | Penguard Express WF II |
|---|---|
| Manufacturer product name | 6X7 |
| Resin system | auxiliary material |
| Components | one-component |
| Typical number of coats | inhibitor |
| Service environment | as the system requires |
| Suitable substrates | carbon steel / galvanised steel / stainless steel / concrete |
| Key characteristics | fast-drying / high-build |
| Colour range | As the system requires |
| Application method | add to the companion coating |
| Surface preparation grade | sa 2½ / st 2 |
| Volume solids | 55 % ± 2 % |
| Density (specific gravity) | 1.35 kg/l |
| Flash point | 100 °C |
| Gloss | Matt (0-35) |
| Packaging and delivery | Supplied in full drums or full pallets, with staged deliveries to match the progress on site; pack sizes are confirmed per model |
| Source | Manufacturer technical data sheet (jotun-penguard-express-wf-ii.pdf) |
Application and system notes
Application: add to the companion coating (sa 2½ / st 2). Before application, confirm the surface preparation grade and control ambient temperature and humidity, substrate temperature and dew point as the manufacturer requires; observe the specified recoat intervals.
Drying and curing times
| Substrate temperature | 5 °C | 10 °C | 23 °C | 40 °C |
|---|---|---|---|---|
| Touch dry | 6 h | 5 h | 2.5 h | 1 h |
| Walk-on dry | 24 h | 20 h | 8 h | 5 h |
| Recoat, minimum | 24 h | 20 h | 8 h | 5 h |
| Dried/cured for service | 15 d | 12 d | 7 d | 3 d |
Data taken from the manufacturer's TDS jotun-penguard-express-wf-ii.pdf (page 4); 23 °C is the reference condition, the other columns are given for application in different seasons and regions. The full data sheet is available from us on request.
Usually applied as inhibitor; the number of coats and the quantity per unit depend on the surface condition of the carbon steel / galvanised steel / stainless steel / concrete and the corrosivity of the as the system requires environment.
Standards and approvals
- GB 30981.2
- GB 30981.2-2025
- ISO 12944-2
- ISO 2813
- ISO 3233
- ISO 3679
- ISO 8501-1
Standards and approvals for Penguard Express WF II follow the manufacturer's current technical data sheet; tell us the purpose and the recipient if you need scanned certificates.
Penguard Express WF II — requesting technical data
Volume solids, recommended dry film thickness, theoretical spreading rate, drying and curing times and VOC are itemised in the manufacturer's technical data sheet (TDS).
Full documentation — TDS, SDS, test and certification documents — is available on request: quote the model Penguard Express WF II and the intended use.
Penguard Express WF II — common questions
What are the key characteristics of Penguard Express WF II?
This model offers fast-drying / high-build. Suitability for a particular service condition still has to be assessed together with the complete coating system.
How is the recoat interval for Penguard Express WF II controlled?
The minimum and maximum recoat intervals follow the manufacturer's TDS and must also satisfy the on-site temperature, humidity and dew point conditions.
Which substrates can Penguard Express WF II be used on?
The TDS lists the substrate as carbon steel / galvanised steel / stainless steel / concrete; surface preparation must be completed and cleanliness and roughness confirmed, and ambient temperature, humidity and dew point must be within limits before coating.
Models related to Penguard Express WF II
Back to Products to filter every model by use or type
Model and category information on this page is compiled from the manufacturer's technical data sheets and is provided for selection reference; parameters, application requirements and suitability are governed by the manufacturer's latest technical data sheet and by the actual site conditions. This site does not replace the manufacturer's documents.
Sales & technical support
Detailed data and a quotation for Penguard Express WF II
We supply Jotun industrial coatings made in China and handle the export. Get in touch.
- WhatsApp Start a chat
- Email max@rich-tech.net