Penguard Fulfill SF epoxy
China-based distributor of Jotun industrial protective coatings — supplied from the China production base to projects worldwide.
This model belongs to the categories below; select a tag to see every model in that category.
Penguard Fulfill SF — product overview
This is a two-component epoxy product, typically used as filler. It is characterised by manufactured to the manufacturer's technical data sheet; service environment atmospheric exposure; suitable for protective coating of carbon steel / concrete.
Penguard Fulfill SF — positioning
Penguard Fulfill SF (06B) is the epoxy filler in the Jotun range; this page sets out its system position, parameters and supply.
The substrate for this product is carbon steel / concrete. Prepare the surface as the manufacturer requires, and check ambient temperature, humidity and dew point before starting.
This model is manufactured to the manufacturer's technical data sheet.
It is used for protective coating work in atmospheric exposure conditions.
Penguard Fulfill SF — key data
| Model | Penguard Fulfill SF |
|---|---|
| Manufacturer product name | 06B |
| Resin system | epoxy |
| Components | two-component |
| Typical number of coats | filler |
| Service environment | atmospheric exposure |
| Suitable substrates | carbon steel / concrete |
| Colour range | White |
| Application method | airless spray / brush / roller |
| Surface preparation grade | sa 2½ |
| Volume solids | 97 % ± 2 % |
| Density (specific gravity) | 1.8 kg/l |
| Packaging and delivery | Supplied in full drums or full pallets, with staged deliveries to match the progress on site; pack sizes are confirmed per model |
| Source | Manufacturer technical data sheet (jotun-penguard-fulfill-sf.pdf) |
Application and system notes
Application: airless spray / brush / roller (sa 2½). Before application, confirm the surface preparation grade and control ambient temperature and humidity, substrate temperature and dew point as the manufacturer requires; observe the specified recoat intervals.
Drying and curing times
| Substrate temperature | 5 °C | 10 °C | 23 °C | 40 °C |
|---|---|---|---|---|
| Touch dry | 5 h | 5 h | 3 h | 2 h |
| Walk-on dry | 48 h | 33 h | 14 h | 6 h |
| Recoat, minimum | 48 h | 33 h | 14 h | 6 h |
| Dried/cured for service | 21 d | 14 d | 7 d | 3 d |
Data taken from the manufacturer's TDS jotun-penguard-fulfill-sf.pdf (page 4); 23 °C is the reference condition, the other columns are given for application in different seasons and regions. The full data sheet is available from us on request.
Coat sequence, film thickness and quantity depend on the service conditions (carbon steel / concrete / atmospheric exposure) and the design life: give us the structure type, corrosivity category and area, and the quantity can be calculated.
Standards and approvals
- GB 30981-2020
- GB 38508-2020
- ISO 3233
- ISO 8501-1
- NACE No. 6
Standard numbers are given for selection checks; valid, in-date documents for formal tenders or acceptance are supplied per model.
Penguard Fulfill SF — requesting technical data
Volume solids, recommended dry film thickness, theoretical spreading rate, drying and curing times and VOC are itemised in the manufacturer's technical data sheet (TDS).
Full documentation — TDS, SDS, test and certification documents — is available on request: quote the model Penguard Fulfill SF and the intended use.
Penguard Fulfill SF — common questions
What are the key characteristics of Penguard Fulfill SF?
This model offers manufactured to the manufacturer's technical data sheet. Suitability for a particular service condition still has to be assessed together with the complete coating system.
How is the recoat interval for Penguard Fulfill SF controlled?
The minimum and maximum recoat intervals follow the manufacturer's TDS and must also satisfy the on-site temperature, humidity and dew point conditions.
Which substrates can Penguard Fulfill SF be used on?
The TDS lists the substrate as carbon steel / concrete; surface preparation must be completed and cleanliness and roughness confirmed, and ambient temperature, humidity and dew point must be within limits before coating.
Models related to Penguard Fulfill SF
Back to Products to filter every model by use or type
Model and category information on this page is compiled from the manufacturer's technical data sheets and is provided for selection reference; parameters, application requirements and suitability are governed by the manufacturer's latest technical data sheet and by the actual site conditions. This site does not replace the manufacturer's documents.
Sales & technical support
Detailed data and a quotation for Penguard Fulfill SF
We supply Jotun industrial coatings made in China and handle the export. Get in touch.
- WhatsApp Start a chat
- Email max@rich-tech.net